The Ultrasonic IRIS option is used to inspect a wide range of materials, including ferrous, nonferrous, and non-metallic tubing. This technique detects and sizes wall loss resulting from corrosion, erosion, wear, pitting, cracking, and baffle cuts.
The IRIS inspection technology is used extensively as a prove-up technique for remote field testing, magnetic flux leakage, and eddy current inspections.
Works on all materials, regardless of properties.
Full sensitivity near tube support structures such as tubesheets.
Perfect as a backup to electromagnetic testing.
Very accurate wall thickness measurement results.