IR sensor: 1024 × 768 (786,432 measurement pixels)
Thermal sensitivity/NETD: < 0.02°C at +30°C
Lens choices: 12°, 28°, 45°, 3x
Close-up Minimum focus distance: 0.2m (0.66 ft.) to 0.8m (2.13 ft.), depending upon the lens
Image frequency: 30 Hz
Spectral range: 7.5 – 14 µm 4.3” display 800 x 480 pixels
Auto orientation
Touch screen
UltraMax™: Unique super-resolution process quadruples pixel count, up to 3.1 MP
MSX®: Embosses visual details on full resolution thermal image, for clear text and location identification
Measure temperature ranges of 40 to +2000ºC
Accuracy: ±1°C (±1.8°F) or ±1% @25ºC for temperatures between 5ºC to 150ºC ±2°C (±3.6°F) or ±2% of reading @ 25ºC for temperatures up to 1200ºC
Measurement tools: 10 spotmeters, 5+5 areas (boxes, circles) with min./max./average
Emissivity correction: Variable from 0.01 to 1.0 or selected from materials list
Measurements correction: Emissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external IR window compensation
Colour palettes: Iron, Rainbow, Rainbow HC, White Hot, Black Hot, Arctic, Lava