Agilent PHD-4 Portable Helium Leak Detector

A portable helium leak detector maximising productivity and uptime

Agilent PHD-4 Portable Helium Leak Detector

About

The PHD-4 sniffer leak detector is able to detect very small leaks in objects that have a slight helium/air pressure inside.
Agilent PHD-4 Portable Helium Leak Detector The lightweight and rugged sniffer is sensitive to helium concentrations as small as 2 ppm- equivalent to a leak rate of 5x 10-6 atm-cc/sec, far superior to the performance by other means of detecting leaks, such as bubble-testing. The PHD-4 sensitivity relies on Agilent’s proprietary and patented SIPD (Selective Ion Pump Detection) technology. Since it is controlled by a microprocessor, the PHD-4 is easy to use with no training required. All tuning and zeroing are handled automatically. The display can be set to use any of four languages (English, French, German, and Italian).

A easy to use, no training required, portable helium detector suitable for a range of environments including large vessels & bioreactors, underground pipes & storage tanks, water heating & cooling pipes, and aeroplane fuel tanks & lines. The PHD-4 is in daily use in many other applications. Its portability makes it ideal for factory and field maintenance in areas such as:

  • Components and systems for the Chemical and Petrochemical Industries
  • Compressed air components and delivery systems
  • Process gas delivery lines in Semiconductor fabrication industry

Additional Information

  • The PHD-4 weighs only 2,6 Kg (5.7 lbs) including the battery
  • Wide range of uses: replaces or can be used with existing methods such as bubble test or pressure decay
  • State-of-the-art microprocessor control allows great simplicity of operation
  • Fully automatic start-up
  • Ready for test in less than 3 minutes
  • Excellent selectivity for helium allows you to read helium leaks and ignore all other gases
  • Helium sensitivity can be adjusted as required to minimize test costs and helium consumption
  • Can operate either on battery power or connected to an outlet

Features

  • Smallest detectable leak: 2 parts per million
  • Lowest detectable helium concentration:
    5 × 10-6 atm-cc/sec
    5 × 10-6 mbar-l/sec
    5 × 10-7 Pa-m3/sec
  • Start-up time, including self-check: 3 minutes (approximate)
  • Power requirements: 12 VDC from battery pack, car battery, or transformer
  • Transformer power supply: 110-240V 50-60 Hz
  • Sealed, detachable battery pack: 4 hours of operation with full charge
  • Ambient storage temperature: -20 to +60 °C (4 to 140 °F)
  • Ambient operating temperature: -5 to +35 °C (20 to 95° F)
  • Maximum relative humidity: 90% Weight, basic module with battery 5.7 lbs (2.6 kg)
  • Background suppression (zeroing): Automatic
  • Tuning: Automatic