Performance
|
| Radiation detected |
X-rays and gamma rays
in range 59 keV to 1332 keV
|
Accumulated dose range |
Digital numeric display
0–10,000 µSv
0–1,000 mrem
|
| Detector |
Single halogen, energy compensated
Geiger Muller tube
|
Peak radiation dose rate |
Digital numeric display
0–10,000 µSv/h
0–1,000 mrem/h
|
| Dose rate range |
Bar graph display: 0–1000 µSv/h
Digital numeric display:
0–10,000 µSv/h
0–1,000 mrem/h
|
|
|
|
Electrical characteristics
|
| Battery |
Varta Hi Energy 6LP3146 |
Low battery indication |
On 4 hours battery life remaining |
| Battery life |
100 hours typically with background radiation
|
Variation with battery voltage |
Less than 2% |
|
Mechanical characteristics
|
| Case material |
Static dissipative nylon body
with ABS window
|
Weight |
500 grammes |
|
Environmental
|
| Variation with temperature |
Less than 15% over operating temperature range
|
Humidity range |
0 – 95% |
| Ingress protection rating |
Rated IP65 (dust tight and will withstand water jets)
|
Hazardous area certification code |
ATEX: Certification No. Baseefa05ATEX0151
Marking – Ex ia IIC T4 Ga (−20°C ≤ Ta ≤ +50°C)
IECEx: Certification No. IECEx BAS 05.0064
Marking – Ex ia IIC T4 Ga (−20°C ≤ Ta ≤ +50°C)
|
| Hazardous area classification code |
ATEX & IECEx: Zone 0, 1, 2
gas group IIA, IIB, IIC
|
Standard compliance |
BS EN 60846, EN55011,
IEC60079-0, IEC60079-11,
IEC61010-1
|